Feds: 2018 fire that injured 23 workers caused by multiple process safety issues
An investigation into the 2018 fire that injured 23 workers at the Kuraray America chemical plant in Texas was caused by 17 safety issues, including multiple process safety failures, according to the U.S. Chemical Safety and Hazard Investigation Board (CSB).

The CSB report offers a dozen recommendations on how the company can prevent a similar incident from occurring.

2,300 pounds of ethylene released in 3 minutes


On May 19, 2018, a chemical reactor system startup that occurred following a scheduled maintenance shutdown caused high pressure conditions inside the reactor.

The high pressure activated the reactor’s emergency pressure release system, discharging flammable ethylene vapor through piping into an area where several contractors were working. More than 2,300 pounds of ethylene were released in three minutes.

Work being done by the contractors included welding, which “most likely ignited the flammable vapor,” according to the CSB.
Twenty-three workers were injured during the incident, with two needing to be life-flighted from the facility and another remaining in critical condition for several days due to burn injuries. Nineteen other workers were transported to the hospital for various injuries.




Incident caused by ‘chain of process safety failures’


CSB investigators determined that the cause of the incident was Kuraray’s emergency pressure relief system design, which discharged the flammable ethylene vapor from the reactor through horizontally aimed piping into the air in an area near workers.

If this pressure release system had been designed to discharge vapor into a safe location, the flammable gas wouldn’t have harmed any workers, according to CSB investigators.

“Kuraray also should have evacuated these workers from the area when the reactor’s high-pressure alarm sounded, since it was signaling a serious problem with the reactor,” CSB Chairperson Steve Owens said.

Investigators found “a chain of process safety management failures that led to the build-up of excessive pressure inside the reactor.”

Those failures include:

  • emergency pressure relief system discharge design

  • presence of nonessential workers during startup and upset conditions

  • hazardous location

  • recognized and generally accepted good engineering practices

  • process hazard analysis safeguards

  • process hazard analysis recommendations

  • warning signs

  • equipment design

  • operating procedures

  • operator training

  • abnormal operating conditions

  • safety interlock disabling

  • alarm management

  • process alarm response

  • safe operating limits

  • environmental permit limits, and

  • safety management system self-assessment audits.


12 ways to avoid a repeat incident


The CSB advised Kuraray America to follow 12 recommendations to avoid a repeat of this incident.

Those recommendations include:

  • developing an emergency pressure relief system design standard to ensure discharge to safe locations

  • implementing a site-wide system to evacuate nonessential personnel during startup and certain other conditions

  • developing a system requiring periodic evaluation of the effectiveness of any safeguard used to lower the risk of process safety hazards

  • developing a policy detailing how to effectively address recommendations generated from company process safety management systems

  • reviewing the Center for Chemical Process Safety guidance on recognizing catastrophic incident warning signs and developing a program incorporating warning signs into the safety management system

  • clarifying the lower equipment design pressure of the reactor within operator training systems, written procedures and control system interfaces

  • developing a program ensuring the plant’s nightly operating instructions don’t conflict with its written operating procedures

  • strengthening the plant’s operator training program

  • completing the plant’s alarm management efforts and implementing a continual program to meet alarm rate performance targets

  • improving the plant’s safety management system

  • modifying the plant’s safe operating limits program to prevent operating under conditions that rely on equipment design factors, and

  • acquiring the services of an independent third party to perform a comprehensive assessment of the plant’s process safety management systems.



SOURCE: